毕业论文 基于simplici ti无线火灾报警系统的设计.doc
约25页DOC格式手机打开展开
毕业论文 基于simplici ti无线火灾报警系统的设计,摘要现有火灾报警主要采用有线方式,耗费材料、故障率高且难于实现互联报警。采用无线方式能够很好的解决互联报警、降低成本。利用msp430f227 +cc250搭载simplici ti实现节点互联,数据中心节点连接至pc机,pc机能实时监控节点信息,在火灾到来时能够及时准确的实现本地报警和远程报警。本设计的火灾节点为超低...
内容介绍
此文档由会员 ljjwl8321 发布
摘要
现有火灾报警主要采用有线方式,耗费材料、故障率高且难于实现互联报警。采用无线方式能够很好的解决互联报警、降低成本。利用MSP430F227 +CC250搭载Simplici Ti实现节点互联,数据中心节点连接至PC机,PC机能实时监控节点信息,在火灾到来时能够及时准确的实现本地报警和远程报警。本设计的火灾节点为超低功耗,休眠时只有不到1uA电流。它具有较强的工程实践意义和应用前景。
关键词:SimpliciTi;MSP430;烟雾传感器;GPRS模块
Abstract
Existing fire alarm system adopts cable way. It expends materials and has a high failure rate,it also hard to implement interconnected alarm. Using wireless means can solve interconnected alarm and reduce costs very well. Using MSP430F227 + CC250 together with Simplici Ti protocol can realize nodes interconnected. Make the access point connecte to the PC , PCS monitors node information in real-time,it can realize local alarm and remote alarm timely and accurately when the fire comes. The fire node in this design uses ultralow-power consumption, Its standby current is less than 1uA. It has strong engineering practical significance and application prospect.
Key words:SimpliciTi;MSP430;Smoke sensor;GPRS module
目录
摘要 I
ABSTRACT I
1引言 1
2系统设计 1
2.1设计要求 1
2.2总体设计方案 1
2.2.1无线网络协议选择【1】 1
2.2.2 Simplici Ti网络协议【1】 2
2.2.3单片机选型 4
2.2.4烟雾传感 5
2.2.5远程报警 5
2.2.6 系统框图 6
3分布式采集节点设计 6
3.1节点硬件设计 6
3.2节点软件设计 9
3.2.1软件开发环境及语言【4】 9
3.2.2火灾探测节点软件设计 9
3.2.3数据接入点软件设计 10
4监控报警系统设计 10
4.1 GSM远程报警模块 10
4.2监控报警系统界面设计 11
4.3监控报警系统软件流程 12
5系统测试 13
5.1系统覆盖范围测试 13
5.2节点功耗测试 14
5.3 GSM报警模块通信测试 15
5.4系统整机测试 15
5.4.1火灾温度报警测试 16
5.4.2火灾烟雾报警测试 16
6总结与展望 17
致谢 17
参考文献 18
附录 18
元器件清单 18
原理图 19
PCB 19
实物图 20
现有火灾报警主要采用有线方式,耗费材料、故障率高且难于实现互联报警。采用无线方式能够很好的解决互联报警、降低成本。利用MSP430F227 +CC250搭载Simplici Ti实现节点互联,数据中心节点连接至PC机,PC机能实时监控节点信息,在火灾到来时能够及时准确的实现本地报警和远程报警。本设计的火灾节点为超低功耗,休眠时只有不到1uA电流。它具有较强的工程实践意义和应用前景。
关键词:SimpliciTi;MSP430;烟雾传感器;GPRS模块
Abstract
Existing fire alarm system adopts cable way. It expends materials and has a high failure rate,it also hard to implement interconnected alarm. Using wireless means can solve interconnected alarm and reduce costs very well. Using MSP430F227 + CC250 together with Simplici Ti protocol can realize nodes interconnected. Make the access point connecte to the PC , PCS monitors node information in real-time,it can realize local alarm and remote alarm timely and accurately when the fire comes. The fire node in this design uses ultralow-power consumption, Its standby current is less than 1uA. It has strong engineering practical significance and application prospect.
Key words:SimpliciTi;MSP430;Smoke sensor;GPRS module
目录
摘要 I
ABSTRACT I
1引言 1
2系统设计 1
2.1设计要求 1
2.2总体设计方案 1
2.2.1无线网络协议选择【1】 1
2.2.2 Simplici Ti网络协议【1】 2
2.2.3单片机选型 4
2.2.4烟雾传感 5
2.2.5远程报警 5
2.2.6 系统框图 6
3分布式采集节点设计 6
3.1节点硬件设计 6
3.2节点软件设计 9
3.2.1软件开发环境及语言【4】 9
3.2.2火灾探测节点软件设计 9
3.2.3数据接入点软件设计 10
4监控报警系统设计 10
4.1 GSM远程报警模块 10
4.2监控报警系统界面设计 11
4.3监控报警系统软件流程 12
5系统测试 13
5.1系统覆盖范围测试 13
5.2节点功耗测试 14
5.3 GSM报警模块通信测试 15
5.4系统整机测试 15
5.4.1火灾温度报警测试 16
5.4.2火灾烟雾报警测试 16
6总结与展望 17
致谢 17
参考文献 18
附录 18
元器件清单 18
原理图 19
PCB 19
实物图 20