负载运行的变压器及直流电机导论负载运行的变压器---------外文翻译(外文原文+中文翻译).doc

约21页DOC格式手机打开展开

负载运行的变压器及直流电机导论负载运行的变压器---------外文翻译(外文原文+中文翻译),it has been shown that a primary input voltage can be transformed to any desired open-circuit secondary voltageby a suitable choice of turn’s ratio. is availabl...
编号:10-270297大小:400.50K
分类: 论文>外文翻译

内容介绍

此文档由会员 wanli1988go 发布

It has been shown that a primary input voltage can be transformed to any desired open-circuit secondary voltage by a suitable choice of turn’s ratio. is available for circulating a load current impedance. For the moment, a lagging power factor will be considered. The secondary current and the resulting ampere-turns will change the flux, tending to demagnetize the core, reduce and with it . Because the primary leakage impedance drop is so low, a small alteration to will cause an appreciable increase of primary current from to a new value of equal to . The extra primary current and ampere-turns nearly cancel the whole of the secondary ampere-turns. This being so, the mutual flux suffers only a slight modification and requires practically the same net ampere-turns as on no load. The total primary ampere-turns are increased by an amount necessary to neutralize the same amount of secondary ampere-turns. In the vector equation, ; alternatively, . At full load, the

通过选择合适的匝数比,一次侧输入电压 可任意转换成所希望的二次侧开路电压 。 可用于产生负载电流,该电流的幅值和功率因数将由而次侧电路的阻抗决定。现在,我们要讨论一种滞后功率因数。二次侧电流及其总安匝 将影响磁通,有一种对铁芯产生去磁、减小 和 的趋向。因为一次侧漏阻抗压降如此之小,所以 的微小变化都将导致一次侧电流增加很大,从 增大至一个新值 。增加的一次侧电流和磁势近似平衡了全部二次侧磁势。这样的话,互感磁通只经历很小的变化,并且实际上只需要与空载时相同的净磁势 。一次侧总磁势增加了 ,它是平衡同量的二次侧磁势所必需的。在向量方程中, ,上式也可变换成 。满载时,电流 只约占满载电流的5%,因而 近似等于